Your staffing plan looks solid. Temporary hires have badges, the schedule has shifts, and the dock calendar has no open doors. Then the first heavy week arrives. A supervisor loses ten minutes walking to the back corner of the building, because the radio can’t reach it.
Most distribution centers plan labor, inventory, and carrier capacity well ahead of the holidays. A peak season communication plan rarely makes that list. It should, because every other plan depends on people reaching each other quickly.
Peak season no longer arrives on a schedule
This year showed how unpredictable the calendar has become. The National Retail Federation reported that retailers brought in merchandise early to get ahead of tariff changes and other supply chain uncertainty. The peak started early and stretched through summer and early fall. According to MH&L, August likely ended up the busiest month of the year, and most holiday merchandise has already arrived.
For a distribution center, that matters in two ways. Many facilities have run busy for longer than a typical season. And the holiday push now lands on outbound operations, where more people and more devices share the same floor.
Small communication gaps cost more when volume is high
On a normal day, a missed radio call costs a few minutes. During peak, the same gap ripples through the building. A dock team waits on a supervisor while a carrier idles at the door. A picker can’t confirm a location, so an order slips past the cutoff. A forklift operator can’t flag a blocked aisle, so a second operator drives into it.
None of these problems comes from a lack of effort. They come from a communication system that fits an average week, not a peak one.
Build your peak season communication plan around coverage first
Peak season changes your building. Temporary racking goes up, pallets fill the aisles, and trailers sometimes serve as overflow storage. Each change can alter how radio signal travels. Steel racking and sorters already make large buildings hard to cover, and a full building behaves differently than a half empty one.
Walk the floor with a radio during a busy shift, not on a quiet morning. Check the dock doors, the mezzanine, the back corners, and any area where inventory has moved. Test in both directions. Call someone from each spot, then have them call you back, because a radio can receive a call clearly and still struggle to send one.
Note every spot where audio drops, cuts out, or turns choppy. Mark each one on a floor plan with the time and the radio you used. That map becomes the most useful document you have when you talk with a radio provider.
Cold storage needs its own attention. Insulated freezer and cooler sections block signal, and workers in those areas can least afford to lose contact. If your building has them, test inside and at the doors.
Then check the yard and the guard shack. Drivers and yard staff need to reach the floor just as much as your pickers do. If you run more than one building on a campus, test the link between them, too.
Forklifts deserve a look as well. A mounted radio with a speaker mic lets operators communicate while their hands stay on the controls. It also stays with the vehicle, so nobody loses it or leaves it on a charger when operators change shifts.
Count your devices before the temporary hires arrive
Extra headcount means extra radios. Count what you have, and list what you still need. Number each device so you know who holds what at the start of every shift.
Stock spare batteries, headsets, and speaker mics. Make sure your charging capacity matches your busiest shift pattern, so no radio leaves the charger half full.
Decide how you will handle repairs, too. A short turnaround means fewer idle devices. At AWC, we repair radios in our own facility and provide four-day turn times.
Give each team a channel and a way to escalate
More people on one channel means more chatter and more missed calls. During peak, a single shared channel can turn into a constant stream of traffic, and the urgent call gets buried. Assign channels by function, such as inbound, outbound, dock, yard, and maintenance, so each team hears only what applies to it. Then decide how supervisors will reach every group when they need to.
If you need additional frequencies, plan for FCC licensing lead time. Our in-house FCC coordinators handle that paperwork, and starting early keeps it from slowing your rollout.
Decide who to call when a radio fails. A short card with the primary contact, a backup, and the first steps to try saves supervisors from guessing in the moment. Post it where supervisors can find it quickly, and share it before the rush, not during it.
How AWC helps
Reliable radio coverage in a large building with steel racking and sorters takes careful design. Our engineers design radio systems for distribution centers, and every installation includes detailed signal strength testing with documentation.
If you’re still sorting out where your coverage stands, our team can review your floorplans and show where signal is likely to fall short. If you already know which areas keep dropping out, we can design a fix and test it with documented readings. Reach out through our contact page, email awc-sales@advancedwireless.com, or call 800.475.5852.